Under the influence of power grid short-circuit impacts, transportation vibrations, and long-term operating stress, transformer windings are highly susceptible to displacement, bulging, or inter-turn short circuits. To address this issue, four transformer winding deformation testers—ZX-BRY01, ZX-BRY02B, ZX-BRY03, and ZX-BRY04—provide users with quantitative diagnostic data from both frequency response method (FRA) and impedance method perspectives, fully meeting the requirements of DL/T911-2016 and DL/T1093-2018 standards.

I. ZX-BRY01 (Dual-function Industrial Control Unit)—High-end Mainstream Power Grid Unit Suitable for 63kV~500kV power transformers.
  • Frequency response range: 10Hz~10MHz, up to 40,000 sweep points, resolution 0.25kHz
  • Amplitude measurement range: -120dB~+20dB, accuracy ≤1dB
  • Impedance measurement accuracy: Voltage 0.2%, Current 0.2%
  • Output signal: ±20V, frequency accuracy ≤0.01%

Its advantages lie in the integration of frequency response and impedance measurement, with a built-in industrial computer operating independently, supporting three-phase automatic analysis and Word report generation. Suitable for provincial power research institutes and maintenance companies to establish long-term databases.

II. ZX-BRY02B (Portable Standalone Model) – A Powerful Tool for Rapid On-Site Testing
  • Frequency range: 100Hz~2MHz
  • Resolution: 0.1kHz
  • Frequency response resolution: 0.1dB
  • Single-phase test time: Approximately 60 seconds
  • Built-in FLASH can store 1000 sets of data.

Employs 32-bit ARM+DDS technology, a 10.1-inch touchscreen, and can be operated without a computer. Lightweight and compact (415×350×140mm), suitable for maintenance team inspections and rapid troubleshooting at new energy power plants.

III. ZX-BRY03 (Standard Laboratory Type) – High-Precision Analysis Platform
  • Frequency Sweep Range: 10Hz~10MHz
  • Frequency Accuracy: 0.005%
  • Amplitude Accuracy: 0.1dB
  • Repeatability: 99.9%
  • Weight: 20kg

Supports both linear and segmented frequency sweep modes, can load up to 6 curves for comparison, and features an expert intelligent diagnostic system. Suitable for comparative analysis before and after major transformer overhauls.

IV. ZX-BRY04 (Enhanced Dual-Method Integration) – Intelligent Comprehensive Diagnostic Platform

Based on the BRY03, the impedance method module is enhanced:

  • Impedance Range: 0~100%
  • Voltage Measurement: 25V~500V
  • Current Measurement: 0.1A~10A
  • Three-phase automatic measurement error criterion: Phase-to-phase ≤2.5%, In-phase ≤2%

Supports internal/external power supply switching, automatically determines if the current exceeds 10A, avoiding the risk of incorrect connection. Suitable for rapid re-inspection after short circuits in 110kV and above transformers.

The core problems solved:
  • Determining whether winding displacement or deformation has occurred (quantitative analysis of frequency response curve deviation)
  • Determining whether it can withstand short-circuit impact (impedance change rate comparison)
  • Establishing a database comparing factory and operational cycles (≥6-year cycle retesting)
  • Avoiding disassembly and inspection by lifting the casing, reducing maintenance costs by more than 30%
In summary:
  • For comprehensive functionality and high voltage level coverage—choose ZX-BRY01/04
  • For portable inspection—choose ZX-BRY02B
  • For laboratory accuracy and in-depth curve analysis—choose ZX-BRY03

These four products form a complete technical team from on-site operation and maintenance to scientific research diagnosis, providing quantitative and traceable data assurance for the safe operation of transformers.